  Datasheet File OCR Text:
  data sheet pxj pxj5 pxj3 fc series receiving instruments, converters, computa- tional units and distributors which are mountable on instru- ment panels are designed in principle for a power supply of 24v dc. type pxj is a regulated-voltage power supply to be used as a common system power supply unit for providing 24v dc to the panel-mounted instruments from a commercial line power outlet of 100v ac. it adopts a switching regulator system for realizing a compact and highly efficient common system power supply unit. it is also prepared as a common system power supply unit equipped with a battery backup system which permits parallel operation to assure failure- free power supply of even higher reliability. the power supply unit can be equipped further with a protective function against line power failure in cooperation with a digital component. input power supply: 100v or 115v 10% ac, 50/60 hz, single phase output voltage: 25.8v 0.5% dc (with pxj5) 25.8v % dc (with pxj3) output capacity: pxj5 10a pxj3 3a parallel operation: possible for pxj5 only backup with batteries (option): possible for pxj5 only (110v % dc from dc power source or batteries) protective function: protection against shorting (overcurrent drooping characteristic, automatic re- covery ) protection against overvoltage (output voltage interruption at overvoltage, manual reset) efficiency: pxj5 85% typical (100v ac, load 10a) pxj3 80% typical (100v ac, load 3a) input current: pxj5 4.7 a rms typical (100v ac, load 10a) pxj3 1.6 a rms typical (100v ac, load 3a) fc series system power supply unit specifications +0.5 ?.0 +30 ?0 date EDS13-14D aug. 31, 1994
pxj protective function against power failure (option): approx. 30msec after power failure, it is detected to emit power failure signal (open collector on) hold time output held till 40msec after power failure (output 20v dc at input of 90v ac) and then interrupted for approx. 100msec with pxj3 or approx. 500msec with pxj5 alarm output: alarm contact signal provided at output voltage interruption, single contact contact capacity pxj5 .. 220v ac, 3 a/24v dc, 2 a pxj3 .. 100v ac, 0.5 a/24v dc, 0.5a dielectric strength: 1500v ac for one minute between input/output terminal and ground surge protection: with z-trap arrester for primary of power supply insulation resistance: at least 100m ? between each ter- minal and ground as measured with 500v dc megger. ambient temperature: 0 to 45 c ambient humidity: 90% rh (max) mounting: rack mounting mass {weight} approx.: pxj5 ... 7kg pxj3 ... 2.5 kg enclosure: steel case external dimensions (hxwxd): pxj5 ... 247x299x215mm pxj3 ... 247x74x221mm finish color: black code symbols x pj 2 1 345678 description capacity 10a 3a version no. for pxj5 for pxj3 power supply 100v ac, 50/60hz 115v, ac 50/60hz backup with batteries impossible possible (for pxj5 only) protective function against power failure none equipped (only 1 for pxj5) 5 3 0 1 0 1 3 9 2 3
outline diagram (unit : mm) and connection diagram pxj 5 (mounting frame) 210 190 40 175 10 263 (18) (18) 247 235 5 (22) 120 135 299 22 (n?)x300 300 0.5 120 0.5 135 0.5 hole dimensions in mounting frame mounting "n" units sc nf nf alm ac 100 (nf) g eg 19 18 17 16 15 14 13 12 11 dc input + alarm output 110v dc (battery backup) 100v or 115v ac casing ground cr ground noise filter ground shorting plate shorting plate remote sens 0v power common 31 pd + 32 s 33 pc 1 34 pc 2 35 pc 3 36 pc 4 37 sc 38 sc 21 pd 22 s + 23 vp 1 24 vp 2 25 vp 3 26 vp 4 27 sc 28 sc 0v signal common shorting plate 24v dc voltage output + power failure signal remote sens + connection diagram screw m4 235 0.5 215 12.5 +1 0
pxj 1. product name 2. type 3. capacity 4. input power supply 5. application 74 247 221 38 10 210 235 5 switch fuse block terminal 30 hole dimensions in mounting frame 75 0.5 (n?)x75 mounting "n" units 15 30 12.5 215 +1 0 235 0.5 screw m4 connection diagram 11 31 vp 32 pc 33 sc 34 sc 35 sc 36 pd 37 e alm 12 alm 13 ac 14 100 16 g 15 g (nf) 24v dc voltage output + 0v power common power failure signal cr ground 0v signal common alarm output casing ground 100v or 115v ac noise filter ground pxj 3 ordering information information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDS13-14D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X